Hysteretic behavior and strength capacity of shallowly embedded steel column bases with SFRCC slab.

A series of shallowly embedded steel column bases consisting of an exposed column base and a floor slab is tested under horizontal cyclic loading to very large deformation. The effects of floor slabs on strength and ductility are examined using concrete and Steel fiber-reinforced cementitous composi...

Descrición completa

Detalles Bibliográficos
Publicado en:Earthquake engineering & structural dynamics. 40, 13 (2011).
Formato: Artigo
Idioma:English