Engineering considerations for lift-slab construction

"In 1987, the collapse of L'Ambiance Plaza in Bridgeport, Connecticut demonstrated the need to re-evaluate the engineering of lift-slab construction and determine what is needed to make it safe. This re-evaluation was made by the Task Committee on Lift-Slab Construction of the Technical Co...

תיאור מלא

מידע ביבליוגרפי
Main Authors: Zallen, Ruben M. (Author), Peraza, David B. (Author)
מחבר תאגידי: Technical Council on Forensic Engineering (American Society of Civil Engineers)
פורמט: Electronic Resource
שפה:English
יצא לאור: Reston, Virginia American Society of Civil Engineers [2004]
נושאים:
גישה מקוונת:Available for University of the Philippines Diliman College of Engineering via ASCE Library. Click here to access