Thermal performance of a heat pipe with two dissimilar condensers for a minimum-temperature thermal storage system.

An experimental study was conducted to investigate the thermal performance of a heat pipe having two dissimilar condenser sections which were subject to different boundary conditions. The first condenser dissipated heat to the surrounding air through annular fins by natural convection, while the sec...

Full description

Bibliographic Details
Published in:Journal of Applied Science and Engineering 15, 2 (2012).
Main Author: Park, Min Kyu
Format: Article
Language:English
Subjects: