Shaking-table tests of a full-scale single-story masonry veneer wood-frame structure.

This paper presents the findings of shaking-table experiments conducted to examine the seismic performance of a full-scale, one-story, wood-framed structure with masonry veneer. The structure was designed and constructed in accordance with current U.S. code provisions. The veneer was attached to the...

Descripción completa

Detalles Bibliográficos
Publicado en:Earthquake engineering & structural dynamics. 40, 5 (2011).
Autor principal: Okail, Hussein O.
Formato: Artículo
Lenguaje:English
Materias: