Tall building vibration control using a TM-MR damper assembly Experimental results and implementation.

This paper summarizes the relevant results of the design, construction, testing, and implementation of a nominal 120 kN magnetorheological damper developed to control a free-plan tall building in Santiago, Chile, equipped with two 160-ton tuned masses. Cyclic as well as hybrid simulation tests were...

وصف كامل

التفاصيل البيبلوغرافية
الحاوية / القاعدة:Earthquake engineering & structural dynamics. 40, 3 (2011).
المؤلف الرئيسي: Zemp, Rene
التنسيق: مقال
اللغة:English
الموضوعات: