Seismic steel jacketing of rectangular RC bridge columns for the mitigation of lap-splice failures.

This paper investigated the use of external steel jacketing for seismic retrofit of non-ductile reinforced concrete (RC) bridge columns to prevent lap-splice failure. Three 1/2.5 scale specimens were tested under cyclic loads. The effectiveness of two types of steel jackets for improving the ductili...

Mô tả đầy đủ

Chi tiết về thư mục
Xuất bản năm:Earthquake engineering & structural dynamics. 39, 15 (2010).
Tác giả chính: Lin, Min-Lang
Định dạng: Bài viết
Ngôn ngữ:English
Những chủ đề: