A reduced order modeling technique for tall buildings with active tuned mass damper.
It is impractical to install sensors on every floor of a tall building to measure the full state vector because of the large number of degrees of freedom. This makes it necessary to introduce reduced order control. A kind of system reduction scheme (dynamic condensation method) is proposed in this p...
| 出版年: | Earthquake engineering & structural dynamics. 30, 3 (2001). |
|---|---|