Performance of seismic isolated bridges with and without elastic gap devices in near fault zones.

In this paper, the efficiency of providing elastic gap devices (EGDs) to improve the performance of seismic isolated bridges (SIBs) in near fault (NF) zones is investigated. The device is primarily made of an assembly of circular rubber bearings and steel plates to provide additional elastic stiffne...

Täydet tiedot

Bibliografiset tiedot
Julkaisussa:Earthquake engineering & structural dynamics. 37, 6 (2008).
Päätekijä: Dicleli, Murat
Aineistotyyppi: Artikkeli
Kieli:English
Aiheet: