An anthrax "smoke" detector.

We report a method for automated monitoring of airborne endospores, which combines an aerosol capture technique with endospore detection based on terbium luminescence turn-on. We have demonstrated quantification of aerosolized bacterial spores with a response time of ~15 min, a sensitivity of 104 sp...

Full description

Bibliographic Details
Published in:IEEE Engineering in medicine and biology magazine 21, 5 (2002).
Main Author: Lester, E.D
Format: Article
Language:English
Subjects: